  菲尼克斯端子接线有什么留意事项
  1、拧紧力要适中。避免用力过大来松开螺栓和螺母。如果发现螺栓和螺母有松动,请立即更换,不要凑合工作。
  1, tightening force should be moderate. Avoid using too much force to loosen bolts and nuts. If the bolts and nuts are found to be loose, please replace them immediately, do not work at all.
  2、用螺丝刀拧紧或松开螺母时,一定要用螺丝刀用力拧紧螺丝,然后再拧紧或松开,以免螺丝刀与螺丝跑偏,造成螺丝损坏,不易拆卸,特别是在吊箱。
  2. When tightening or loosening the nut with a screwdriver, the screwdriver must be used to tighten the screw forcibly, and then tighten or loosen the screw, so as to avoid deviation between the screwdriver and the screw, resulting in screw damage and difficult to disassemble, especially in the hanging box.
  3、如发现螺栓、螺母难拆装,不必鲁莽行事,以免变形难拆装,应提供适度敲击,或加螺丝松动剂、稀硫酸等拆装前。
  3, if it is found that bolts and nuts are difficult to disassemble, do not act rashly, so as not to disassemble deformation, should provide moderate percussion, or add screw loosening agent, dilute sulfuric acid and other disassembly before.
  4、不要用虎钳拧紧或松开螺栓和螺母,以防损坏。使用活动扳手时,应调整开口,以免螺栓、螺母损坏变形,造成拆卸困难。
  4. Do not tighten or loosen bolts and nuts with a vise to avoid damage. When using an adjustable wrench, adjust the opening to avoid damage and deformation of bolts and nuts, which may cause difficult removal.
  5、同一个菲尼克斯端子允许连接两根以上同类型、同规格的电线。
  5. The same Phoenix terminal is allowed to connect more than two wires of the same type and specification.
  6、对于容易松动或接触不良的接线端子,必须用“?”将接线器紧固在接线端子上。类型以增加总接触面积并避免松动。
  6, for easy to loose or poor contact terminal, must use "?" Fasten the connector to the terminal block. Type to increase the total contact area and avoid loosening.
  7、线接头或线头相互连接时,禁止修改中间的非铜或低导电性垫片。
  7. When wire joints or wire ends are connected to each other, it is forbidden to modify the non-copper or low conductivity gasket in the middle.
  8、连接线材连接器时,规定接触区域清洁,无空气氧化。接线鼻或铜排连接时,接触表面后可将导电膏擦拭干净,然后拧紧。
  8. When connecting the wire connector, the contact area shall be clean without air oxidation. When connecting the wiring nose or copper bar, wipe the conductive paste clean after touching the surface, and then tighten it.
  9、连接临时线时,应将单线铜线的规定端子对折一次,然后接到空气开关的下孔;单芯硬线应收在“?”键入空气开关的下孔。
  9, when connecting the temporary line, the specified terminal of the single wire copper wire should be folded in half once, and then connected to the lower hole of the air switch; Single core hard wire receivable in "?" Type the lower hole of the air switch.
  10、30KW及以上电机的接线,规定电机组出线与电机连接电缆之间不允许使用导电性差的跳线垫圈,如热镀锌螺母、扁垫圈、扭簧垫圈等。
  10. For the wiring of 30KW and above motors, it is stipulated that jumper washers with poor conductivity are not allowed to be used between the outlet line of the generator set and the connecting cable of the motor, such as hot-dip galvanized nuts, flat washers, torsion spring washers, etc.
  11、当用绝缘胶带缠绕电缆或其他机械设备以保持绝缘层时,电缆护套应按压力位置的1/2比例从一端到另一端缠绕,少绕一圈。
  11. When wrapping cables or other mechanical equipment with insulating tape to maintain the insulation layer, the cable sheath should be wound from one end to the other at least once in proportion to the pressure position.